Ingersoll-Rand 2 Stage Air End : The rotors and housing needed repaired on this unit. All items were reconditioned and machined back to OEM specifications and reassembled. Once the new bearings were installed and the clearances set, this unit is ready to ship costing the Customer almost half of the OEM replacement cost in a fraction of the time!
Atlas Copco Single Stage Air End : Improper lubricant over time caused this air end failure. The lubricant attacked the bearing cages and created a hard film throughout the air end that eventually caused the male and female rotor to come into contact with the discharge bearing housing and lock the rotors. A complete repair was completed in 4 days, saving this Customer time and major overhaul dollars versus the OEM replacement option.